Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38622382

RESUMO

BACKGROUND: Sheep have been proposed as a large-animal model for studying cochlear implantation. However, prior sheep studies report that the facial nerve (FN) obscures the round window membrane (RWM), requiring FN sacrifice or a retrofacial opening to access the middle-ear cavity posterior to the FN for cochlear implantation. We investigated surgical access to the RWM in Hampshire sheep compared to Suffolk-Dorset sheep and the feasibility of Hampshire sheep for cochlear implantation via a facial recess approach. METHODS: Sixteen temporal bones from cadaveric sheep heads (ten Hampshire and six Suffolk-Dorset) were dissected to gain surgical access to the RWM via an extended facial recess approach. RWM visibility was graded using St. Thomas' Hospital (STH) classification. Cochlear implant (CI) electrode array insertion was performed in two Hampshire specimens. Micro-CT scans were obtained for each temporal bone, with confirmation of appropriate electrode array placement and segmentation of the inner ear structures. RESULTS: Visibility of the RWM on average was 83% in Hampshire specimens and 59% in Suffolk-Dorset specimens (p = 0.0262). Hampshire RWM visibility was Type I (100% visibility) for three specimens and Type IIa (> 50% visibility) for seven specimens. Suffolk-Dorset RWM visibility was Type IIa for four specimens and Type IIb (< 50% visibility) for two specimens. FN appeared to course more anterolaterally in Suffolk-Dorset specimens. Micro-CT confirmed appropriate CI electrode array placement in the scala tympani without apparent basilar membrane rupture. CONCLUSIONS: Hampshire sheep appear to be a suitable large-animal model for CI electrode insertion via an extended facial recess approach without sacrificing the FN. In this small sample, Hampshire specimens had improved RWM visibility compared to Suffolk-Dorset. Thus, Hampshire sheep may be superior to other breeds for ease of cochlear implantation, with FN and facial recess anatomy more similar to humans.

2.
Hear Res ; 443: 108951, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38277880

RESUMO

Auditory sensation is based in nanoscale vibration of the sensory tissue of the cochlea, the organ of Corti complex (OCC). Motion within the OCC is now observable due to optical coherence tomography. In a previous study (Cooper et al., 2018), the region that includes the electro-motile outer hair cells (OHC) and Deiters cells (DC) was observed to move with larger amplitude than the basilar membrane (BM) and surrounding regions and was termed the "hotspot." In addition to this quantitative distinction, the hotspot moved qualitatively differently than the BM, in that its motion scaled nonlinearly with stimulus level at all frequencies, evincing sub-BF activity. Sub-BF activity enhances non-BF motion; thus the frequency tuning of the OHC/DC region was reduced relative to the BM. In this work we further explore the motion of the gerbil basal OCC and find that regions that lack significant sub-BF activity include the BM, the medial and lateral OCC, and the reticular lamina (RL) region. The observation that the RL region does not move actively sub-BF (already observed in Cho and Puria 2022), suggests that hair cell stereocilia are not exposed to sub-BF activity in the cochlear base. The observation that the lateral and RL regions move approximately linearly sub-BF indicates that linear forces dominate non-linear OHC-based forces on these components at sub-BF frequencies. A complex difference analysis was performed to reveal the internal motion of the OHC/DC region and showed that amplitude structure and phase shifts in the directly measured OHC/DC motion emerge due to the internal OHC/DC motion destructively interfering with BM motion.


Assuntos
Cóclea , Órgão Espiral , Animais , Gerbillinae , Estimulação Acústica , Células Ciliadas Auditivas Externas , Membrana Basilar , Vibração
3.
J Assoc Res Otolaryngol ; 25(1): 53-61, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38238525

RESUMO

PURPOSE: One of the major reasons that totally implantable cochlear microphones are not readily available is the lack of good implantable microphones. An implantable microphone has the potential to provide a range of benefits over external microphones for cochlear implant users including the filtering ability of the outer ear, cosmetics, and usability in all situations. This paper presents results from experiments in human cadaveric ears of a piezofilm microphone concept under development as a possible component of a future implantable microphone system for use with cochlear implants. This microphone is referred to here as a drum microphone (DrumMic) that senses the robust and predictable motion of the umbo, the tip of the malleus. METHODS: The performance was measured by five DrumMics inserted in four different human cadaveric temporal bones. Sensitivity, linearity, bandwidth, and equivalent input noise were measured during these experiments using a sound stimulus and measurement setup. RESULTS: The sensitivity of the DrumMics was found to be tightly clustered across different microphones and ears despite differences in umbo and middle ear anatomy. The DrumMics were shown to behave linearly across a large dynamic range (46 dB SPL to 100 dB SPL) across a wide bandwidth (100 Hz to 8 kHz). The equivalent input noise (over a bandwidth of 0.1-10 kHz) of the DrumMic and amplifier referenced to the ear canal was measured to be about 54 dB SPL in the temporal bone experiment and estimated to be 46 dB SPL after accounting for the pressure gain of the outer ear. CONCLUSION: The results demonstrate that the DrumMic behaves robustly across ears and fabrication. The equivalent input noise performance (related to the lowest level of sound measurable) was shown to approach that of commercial hearing aid microphones. To advance this demonstration of the DrumMic concept to a future prototype implantable in humans, work on encapsulation, biocompatibility, and connectorization will be required.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Orelha Média , Meato Acústico Externo , Cadáver
5.
Laryngoscope ; 134(1): 388-392, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37318112

RESUMO

OBJECTIVES: Oral or intratympanic corticosteroids are commonly used to treat sudden sensorineural hearing loss (SSHL), tinnitus, and Meniere disease. Direct intracochlear delivery has been proposed to overcome the variability in bioavailability and efficacy of systemic or middle ear delivery. In this study, we aim to characterize the physiologic consequences of microneedle-mediated direct intracochlear injection of dexamethasone through the round window membrane (RWM). METHODS: In Hartley guinea pigs (n = 5), a post-auricular incision followed by bullostomy was made to access the round window membrane. Using 100 µm diameter hollow microneedles, 1.0 µl of 10 mg/ml dexamethasone was injected through the RWM over 1 min. Compound action potential (CAP) and distortion product otoacoustic action emissions (DPOAE) were measured before perforation, at 1 h, and at 5 h following injection. CAP hearing thresholds were measured from 0.5 to 40 kHz, and DPOAE f2 frequencies ranged from 1.0 and 32 kHz. Repeated measures ANOVA followed by pairwise t-tests were used for statistical analysis. RESULTS: ANOVA identified significant CAP threshold shifts at four frequencies (4, 16, 36, and 40 kHz) and differences in DPOAE at 1 frequency (6 kHz). Paired t-tests revealed differences between the pre-perforation and 1 h time point. By 5 h post injection, both CAP hearing thresholds and DPOAE recover and are not significantly different from baseline thresholds. CONCLUSION: Direct intracochlear delivery of dexamethasone via microneedles results in temporary shifts in hearing thresholds that resolve by 5 hours, thus supporting microneedle technology for the treatment of inner ear disorders. LEVEL OF EVIDENCE: NA Laryngoscope, 134:388-392, 2024.


Assuntos
Perda Auditiva Neurossensorial , Doença de Meniere , Zumbido , Cobaias , Animais , Audição , Dexametasona
6.
bioRxiv ; 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37873430

RESUMO

Auditory sensation is based in nanoscale vibration of the sensory tissue of the cochlea, the organ of Corti complex (OCC). Motion within the OCC is now observable due to optical coherence tomography. In the cochlear base, in response to sound stimulation, the region that includes the electro-motile outer hair cells (OHC) was observed to move with larger amplitude than the basilar membrane (BM) and surrounding regions. The intense motion is based in active cell mechanics, and the region was termed the "hotspot" (Cooper et al., 2018, Nature comm). In addition to this quantitative distinction, the hotspot moved qualitatively differently than the BM, in that its motion scaled nonlinearly with stimulus level at all frequencies, evincing sub-BF activity. Sub-BF activity enhances non-BF motion; thus the frequency tuning of the hotspot was reduced relative to the BM. Regions that did not exhibit sub-BF activity are here defined as the OCC "frame". By this definition the frame includes the BM, the medial and lateral OCC, and most significantly, the reticular lamina (RL). The frame concept groups the majority OCC as a structure that is largely shielded from sub-BF activity. This shielding, and how it is achieved, are key to the active frequency tuning of the cochlea. The observation that the RL does not move actively sub-BF indicates that hair cell stereocilia are not exposed to sub-BF activity. A complex difference analysis reveals the motion of the hotspot relative to the frame.

7.
J Assoc Res Otolaryngol ; 24(5): 487-497, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37684421

RESUMO

PURPOSE: Sheep are used as a large-animal model for otology research and can be used to study implantable hearing devices. However, a method for temporal bone extraction in sheep, which enables various experiments, has not been described, and literature on middle ear access is limited. We describe a method for temporal bone extraction and an extended facial recess surgical approach to the middle ear in sheep. METHODS: Ten temporal bones from five Hampshire sheep head cadavers were extracted using an oscillating saw. After craniotomy and removal of the brain, a coronal cut was made at the posterior aspect of the orbit followed by a midsagittal cut of the occipital bone and disarticulation of the atlanto-occipital joint. Temporal bones were surgically prepared with an extended facial recess approach. Micro-CT scans of each temporal bone were obtained, and anatomic dimensions were measured. RESULTS: Temporal bone extraction was successful in 10/10 temporal bones. Extended facial recess approach exposed the malleus, incus, stapes, and round window while preserving the facial nerve, with the following surgical considerations: minimally pneumatized mastoid; tegmen (superior limit of mastoid cavity) is low-lying and sits below temporal artery; chorda tympani sacrificed to optimize middle ear exposure; incus buttress does not obscure view of middle ear. Distance between the superior aspect of external auditory canal and tegmen was 2.7 (SD 0.9) mm. CONCLUSION: We identified anatomic landmarks for temporal bone extraction and describe an extended facial recess approach in sheep that exposes the ossicles and round window. This approach is feasible for studying implantable hearing devices.


Assuntos
Otolaringologia , Osso Temporal , Ovinos , Animais , Osso Temporal/cirurgia , Orelha Média , Processo Mastoide/cirurgia , Janela da Cóclea
9.
Otol Neurotol ; 44(5): 513-519, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37026782

RESUMO

HYPOTHESIS: Microneedle-mediated intracochlear injection through the round window membrane (RWM) will facilitate intracochlear delivery, not affect hearing, and allow for full reconstitution of the RWM within 48 hours. BACKGROUND: We have developed polymeric microneedles that allow for in vivo perforation of the guinea pig RWM and aspiration of perilymph for diagnostic analysis, with full reconstitution of the RWM within 48 to 72 hours. In this study, we investigate the ability of microneedles to deliver precise volumes of therapeutics into the cochlea and assess the subsequent consequences on hearing. METHODS: Volumes of 1.0, 2.5, or 5.0 µL of artificial perilymph were injected into the cochlea at a rate of 1 µL/min. Compound action potential (CAP) and distortion product otoacoustic emission were performed to assess for hearing loss (HL), and confocal microscopy was used to evaluate the RWM for residual scarring or inflammation. To evaluate the distribution of agents within the cochlea after microneedle-mediated injection, 1.0 µL of FM 1-43 FX was injected into the cochlea, followed by whole mount cochlear dissection and confocal microscopy. RESULTS: Direct intracochlear injection of 1.0 µL of artificial perilymph in vivo , corresponding to about 20% of the scala tympani volume, was safe and did not result in HL. However, injection of 2.5 or 5.0 µL of artificial perilymph into the cochlea produced statistically significant high-frequency HL persisting 48 hours postperforation. Assessment of RWMs 48 hours after perforation revealed no inflammatory changes or residual scarring. FM 1-43 FX injection resulted in distribution of the agent predominantly in the basal and middle turns. CONCLUSION: Microneedle-mediated intracochlear delivery of small volumes relative to the volume of the scala tympani is feasible, safe, and does not cause HL in guinea pigs; however, injection of large volumes induces high-frequency HL. Injection of small volumes of a fluorescent agent across the RWM resulted in significant distribution within the basal turn, less distribution in the middle turn, and almost none in the apical turn. Microneedle-mediated intracochlear injection, along with our previously developed intracochlear aspiration, opens the pathway for precision inner ear medicine.


Assuntos
Cicatriz , Cóclea , Cobaias , Animais , Cóclea/metabolismo , Rampa do Tímpano , Compostos de Piridínio/metabolismo , Janela da Cóclea , Perilinfa/metabolismo
10.
Hear Res ; 432: 108739, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36966687

RESUMO

BACKGROUND: We have developed 3D-printed microneedle technology for diagnostic aspiration of perilymph and intracochlear delivery of therapeutic agents. Single microneedle-mediated round window membrane (RWM) perforation does not cause hearing loss, heals within 48-72 h, and yields sufficient perilymph for proteomic analysis. In this study, we investigate the anatomic, physiologic, and proteomic consequences of repeated microneedle-mediated perforations of the same RWM at different timepoints. METHODS: 100-µm-diameter hollow microneedles were fabricated using two-photon polymerization (2PP) lithography. The tympanic bullae of Hartley guinea pigs (n = 8) were opened with adequate exposure of the RWM. Distortion product otoacoustic emissions (DPOAE) and compound action potential (CAP) were recorded to assess hearing. The hollow microneedle was introduced into the bulla and the RWM was perforated; 1 µL of perilymph was aspirated from the cochlea over the course of 45 s. 72 h later, the above procedure was repeated with aspiration of an additional 1 µL of perilymph. 72 h after the second perforation, RWMs were harvested for confocal imaging. Perilymph proteomic analysis was completed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). RESULTS: Two perforations and aspirations were performed in 8 guinea pigs. In six, CAP, DPOAE, and proteomic analysis were obtained; in one, only CAP and DPOAE results were obtained; and in one, only proteomics results were obtained. Hearing tests demonstrated mild hearing loss at 1-4 kHz and 28 kHz, most consistent with conductive hearing loss. Confocal microscopy demonstrated complete healing of all perforations with full reconstitution of the RWM. Perilymph proteomic analysis identified 1855 proteins across 14 samples. The inner ear protein cochlin was observed in all samples, indicating successful aspiration of perilymph. Non-adjusted paired t-tests with p < 0.01 revealed significant changes in 13 of 1855 identified proteins (0.7%) between the first and second aspirations. CONCLUSIONS: We demonstrate that repeated microneedle perforation of the RWM is feasible, allows for complete healing of the RWM, and minimally changes the proteomic expression profile. Thus, microneedle-mediated repeated aspirations in a single animal can be used to monitor the response to inner ear treatments over time.


Assuntos
Perda Auditiva , Proteômica , Animais , Cobaias , Cromatografia Líquida , Espectrometria de Massas em Tandem , Janela da Cóclea/metabolismo , Cóclea/metabolismo , Perilinfa/metabolismo , Perda Auditiva/metabolismo
11.
J Acoust Soc Am ; 153(2): 1347, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36859114

RESUMO

Optical coherence tomography (OCT) is a common modality for measuring vibrations within the organ of Corti complex (OCC) in vivo. OCT's uniaxial nature leads to limitations that complicate the interpretation of data from cochlear mechanics experiments. The relationship between the optical axis (axis of motion measurement) and anatomically relevant axes in the cochlea varies across experiments, and generally is not known. This leads to characteristically different motion measurements taken from the same structure at different orientations. We present a method that can reconstruct two-dimensional (2-D) motion of intra-OCC structures in the cochlea's longitudinal-transverse plane. The method requires only a single, unmodified OCT system, and does not require any prior knowledge of precise structural locations or measurement angles. It uses the cochlea's traveling wave to register points between measurements taken at multiple viewing angles. We use this method to reconstruct 2-D motion at the outer hair cell/Deiters cell junction in the gerbil base, and show that reconstructed transverse motion resembles directly measured transverse motion, thus validating the method. The technique clarifies the interpretation of OCT measurements, enhancing their utility in probing the micromechanics of the cochlea.


Assuntos
Tomografia de Coerência Óptica , Vibração , Animais , Órgão Espiral , Cóclea , Movimento (Física) , Gerbillinae
12.
J Assoc Res Otolaryngol ; 24(2): 147-157, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36725777

RESUMO

PURPOSE: A probe that binds to unfixed collagen fibrils was used to image the shapes and fibrous properties of the TM and BM. The probe (CNA35) is derived from the bacterial adhesion protein CNA. We present confocal images of hydrated gerbil TM, BM, and other cochlear structures stained with fluorescently labeled CNA35. A primary purpose of this article is to describe the use of the CNA35 collagen probe in the cochlea. METHODS: Recombinant poly-histidine-tagged CNA35 was expressed in Escherichia coli, purified by cobalt-affinity chromatography, fluorescence labeled, and further purified by gel filtration chromatography. Cochleae from freshly harvested gerbil bullae were irrigated with and then incubated in CNA35 for periods ranging from 2 h - overnight. The cochleae were fixed, decalcified, and dissected. Isolated cochlear turns were imaged by confocal microscopy. RESULTS: The CNA35 probe stained the BM and TM, and volumetric imaging revealed the shape of these structures and the collagen fibrils within them. The limbal zone of the TM stained intensely. In samples from the cochlear base, intense staining was detected on the side of the TM that faces hair cells. In the BM pectinate zone, staining was intense at the upper and lower boundaries. The BM arcuate zone was characterized by a prominent longitudinal collagenous structure. The spiral ligament, limbus and lamina stained for collagen, and within the spiral limbus the habenula perforata were outlined with intense staining. CONCLUSION: The CNA35 probe provides a unique and useful view of collagenous structures in the cochlea.


Assuntos
Membrana Basilar , Membrana Tectorial , Animais , Membrana Basilar/metabolismo , Gerbillinae , Membrana Tectorial/química , Membrana Tectorial/metabolismo , Cóclea/metabolismo , Colágeno/análise , Colágeno/metabolismo , Células Ciliadas Auditivas/química
13.
J Assoc Res Otolaryngol ; 24(2): 117-127, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36648734

RESUMO

In 1985, Bill Brownell and colleagues published the remarkable observation that cochlear outer hair cells (OHCs) express voltage-driven mechanical motion: electromotility. They proposed OHC electromotility as the mechanism for the elusive "cochlear amplifier" required to explain the sensitivity of mammalian hearing. The finding and hypothesis stimulated an explosion of experiments that have transformed our understanding of cochlear mechanics and physiology, the evolution of hair cell structure and function, and audiology. Here, we bring together examples of current research that illustrate the continuing impact of the discovery of OHC electromotility.


Assuntos
Cóclea , Células Ciliadas Auditivas Externas , Animais , Células Ciliadas Auditivas Externas/fisiologia , Audição/fisiologia , Mamíferos
14.
ArXiv ; 2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38196743

RESUMO

Objective: We present the "UmboMic," a prototype piezoelectric cantilever microphone designed for future use with totally-implantable cochlear implants. Methods: The UmboMic sensor is made from polyvinylidene difluoride (PVDF) because of its low Young's modulus and biocompatibility. The sensor is designed to fit in the middle ear and measure the motion of the underside of the eardrum at the umbo. To maximize its performance, we developed a low noise charge amplifier in tandem with the UmboMic sensor. This paper presents the performance of the UmboMic sensor and amplifier in fresh cadaveric human temporal bones. Results: When tested in human temporal bones, the UmboMic apparatus achieves an equivalent input noise of 32.3 dB SPL over the frequency range 100 Hz to 7 kHz, good linearity, and a flat frequency response to within 10 dB from about 100 Hz to 6 kHz. Conclusion: These results demonstrate the feasibility of a PVDF-based microphone when paired with a low-noise amplifier. The reported UmboMic apparatus is comparable in performance to a conventional hearing aid microphone. Significance: The proof-of-concept UmboMic apparatus is a promising step towards creating a totally-implantable cochlear implant. A completely internal system would enhance the quality of life of cochlear implant users.

15.
J Acoust Soc Am ; 151(2): 1115, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35232061

RESUMO

Optical coherence tomography (OCT) has become a powerful tool for measuring vibrations within the organ of Corti complex (OCC) in cochlear mechanics experiments. However, the one-dimensional nature of OCT measurements, combined with experimental and anatomical constraints, make these data ambiguous: Both the relative positions of measured structures and their orientation relative to the direction of measured vibrations are not known a priori. We present a method by which these measurement features can be determined via the use of a volumetric OCT scan to determine the relationship between the imaging/measurement axes and the canonical anatomical axes. We provide evidence that the method is functional by replicating previously measured radial vibration patterns of the basilar membrane (BM). We used the method to compare outer hair cell and BM vibration phase in the same anatomical cross section (but different optical cross sections), and found that outer hair cell region vibrations lead those of the BM across the entire measured frequency range. In contrast, a phase lead is only present at low frequencies in measurements taken within a single optical cross section. Relative phase is critical to the workings of the cochlea, and these results emphasize the importance of anatomically oriented measurement and analysis.


Assuntos
Tomografia de Coerência Óptica , Vibração , Membrana Basilar , Cóclea/diagnóstico por imagem , Células Ciliadas Auditivas Externas , Órgão Espiral , Tomografia de Coerência Óptica/métodos
16.
Hear Res ; 423: 108389, 2022 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-34774368

RESUMO

Intra organ of Corti (OC) vibrations differ from those measured at the basilar membrane (BM), with higher amplitudes and a wide-band nonlinearity extending well below a region's best frequency. The vibrations are boosted by the cochlear amplifier, the active processes within the mammalian hearing organ, and are thus sensitive to metabolic or pharmacological manipulation. We introduced salicylate, a known blocker of outer hair cell (OHC) based electromotility, into the perilymphatic space by applying sodium salicylate onto the round window membrane. Vibration patterns of an area of the OC were mapped with phase sensitive optical coherence tomography before and after treatment; distortion product otoacoustic emissions (DPOAEs) were measured at similar times to assess the cochlear condition. Following treatment, all regions showed a loss of vibration amplitude and tuning while OHC-region vibrations retained their wide-band nonlinearity. OC vibrations, which had been relatively confined in a region including OHCs and extending to the BM at the outer pillar foot, became less confined with structures lateral to the OHCs sometimes exhibiting the highest amplitudes. Vibrations and DPOAEs could recover to baseline levels over approximately three hours post treatment. This article is part of the Special Issue Outer hair cell Edited by Joseph Santos-Sacchi and Kumar Navaratnam.


Assuntos
Salicilatos , Vibração , Animais , Membrana Basilar , Cóclea , Células Ciliadas Auditivas Externas , Mamíferos , Órgão Espiral
17.
Biophys J ; 120(17): 3550-3565, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34384762

RESUMO

The mammalian cochlea relies on the active forcing of sensory outer hair cells (OHCs) to amplify traveling wave responses along the basilar membrane. These forces are the result of electromotility, wherein current through the OHCs leads to conformational changes in the cells that provide stresses on surrounding structures. OHC transducer current can be detected via the voltage in the scala tympani (the cochlear microphonic, CM), and the CM can be used as an indicator of healthy cochlear operation. The CM represents a summation of OHC currents (the inner hair cell contribution is known to be small) and to use CM to probe the properties of OHC transduction requires a model that simulates that summation. We developed a finite element model for that purpose. The pattern of current generators (the model input) was initially based on basilar membrane displacement, with the current size based on in vitro data. The model was able to reproduce the amplitude of experimental CM results reasonably well when the input tuning was enhanced slightly (peak increased by ∼6 dB), which can be regarded as additional hair bundle tuning, and with a current/input value of 200-260 pA/nm, which is ∼4 times greater than the largest in vitro measures.


Assuntos
Membrana Basilar , Células Ciliadas Auditivas Externas , Animais , Cóclea , Células Ciliadas Auditivas Internas , Rampa do Tímpano
18.
J Proteome Res ; 20(8): 4001-4009, 2021 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-34291951

RESUMO

Glucocorticoids are the first-line treatment for sensorineural hearing loss, but little is known about the mechanism of their protective effect or the impact of route of administration. The recent development of hollow microneedles enables safe and reliable sampling of perilymph for proteomic analysis. Using these microneedles, we investigate the effect of intratympanic (IT) versus intraperitoneal (IP) dexamethasone administration on guinea pig perilymph proteome. Guinea pigs were treated with IT dexamethasone (n = 6), IP dexamethasone (n = 8), or untreated for control (n = 8) 6 h prior to aspiration. The round window membrane (RWM) was accessed via a postauricular approach, and hollow microneedles were used to perforate the RWM and aspirate 1 µL of perilymph. Perilymph samples were analyzed by liquid chromatography-mass spectrometry-based label-free quantitative proteomics. Mass spectrometry raw data files have been deposited in an international public repository (MassIVE proteomics repository at https://massive.ucsd.edu/) under data set # MSV000086887. In the 22 samples of perilymph analyzed, 632 proteins were detected, including the inner ear protein cochlin, a perilymph marker. Of these, 14 proteins were modulated by IP, and three proteins were modulated by IT dexamethasone. In both IP and IT dexamethasone groups, VGF nerve growth factor inducible was significantly upregulated compared to control. The remaining adjusted proteins modulate neurons, inflammation, or protein synthesis. Proteome analysis facilitated by the use of hollow microneedles shows that route of dexamethasone administration impacts changes seen in perilymph proteome. Compared to IT administration, the IP route was associated with greater changes in protein expression, including proteins involved in neuroprotection, inflammatory pathway, and protein synthesis. Our findings show that microneedles can mediate safe and effective intracochlear sampling and hold promise for inner ear diagnostics.


Assuntos
Dexametasona/administração & dosagem , Glucocorticoides/administração & dosagem , Perilinfa , Proteoma , Animais , Cobaias , Injeção Intratimpânica , Proteômica
19.
Hear Res ; 405: 108234, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33930834

RESUMO

Studying the in-vivo mechanical and electrophysiological cochlear responses in several species helps us to have a comprehensive view of the sensitivity and frequency selectivity of the cochlea. Different species might use different mechanisms to achieve the sharp frequency-place map. The outer hair cells (OHC) play an important role in mediating frequency tuning. In the present work, we measured the OHC-generated local cochlear microphonic (LCM) and the motion of different layers in the organ of Corti using optical coherence tomography (OCT) in the first turn of the cochlea in guinea pig. In the best frequency (BF) band, our observations were similar to our previous measurements in gerbil: a nonlinear peak in LCM responses and in the basilar membrane (BM) and OHC-region displacements, and higher motion in the OHC region than the BM. Sub-BF the responses in the two species were different. In both species the sub-BF displacement of the BM was linear and LCM was nonlinear. Sub-BF in the OHC-region, nonlinearity was only observed in a subset of healthy guinea pig cochleae while in gerbil, robust nonlinearity was observed in all healthy cochleae. The differences suggest that gerbils and guinea pigs employ different mechanisms for filtering sub-BF OHC activity from BM responses. However, it cannot be ruled out that the differences are due to technical measurement differences across the species.


Assuntos
Membrana Basilar , Células Ciliadas Auditivas Externas , Movimento (Física) , Animais , Cóclea , Gerbillinae , Cobaias
20.
Hear Res ; 405: 108231, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33915400

RESUMO

The middle ear is a high-fidelity, broadband impedance transformer that transmits acoustic stimuli at the eardrum to the inner ear. It is home to the two smallest muscles in mammalian species, which modulate middle ear transmission. Of this pair, the function of the tensor tympani muscle (TTM) has remained obscure. We investigated the acoustic effects of this muscle in young adult gerbils. We measured changes in middle ear vibration produced by pulse-train-elicited TTM contraction - in the time-domain with a click stimulus and in the frequency-domain with multitone zwuis stimuli. In our click experiments, there was generally a small reduction in the primary peak of the response and a slight increase in the subsequent ringing, but there was essentially no change in the delay of the click response at the umbo (less than 1 µs change). In our multitone experiments, there were consistent patterns of attenuation and enhancement in the velocity responses at the umbo and ossicles. TTM contraction produced a narrow band of enhancement around 6 kHz (maximally ~5 dB) that can be modeled with an increased stiffness of an overdamped spring-mass resonance. At frequencies below 2 kHz and above 35 kHz, TTM contraction attenuated middle ear vibrations by as much as fivefold.


Assuntos
Orelha Média , Tensor de Tímpano , Animais , Gerbillinae , Som , Membrana Timpânica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...